ReferenceN-4
®
Notes
10MAY01
Hot wires can be used to cure a delamination with minor affect on the
cosmetics of the part.
Five-minute epoxy, superglue or molten ICW06 can be used to repair
broken models.
In addition to D-Limonene, chemicals such as Tetrahydrofuran (THF),
Methyl Chloride, and Trichloroethylene are solvents for ICW06, but all
should be used with extreme caution.
Moving the Z Stage While Modeling
Stratasys recommends that you do not move the Z stage while building
models. Moving the Z stage causes the model to be inaccurate because
the FDM modeler does not keep its last Z stage position in its memory.