1) Set the liquefier and envelope temperatures on the control panel using the
temperature adjustment buttons.
Changing the FDM Tip
Before proceeding, make sure;
1) the Z stage platen is at least 6 inches below the FDM head.
2) the FDM head is mounted to the FDM .
3) the liquefier is heated to the correct temperature.
Usage—Modeling Operations
Material Tip Size Model Temp Support Temp Envelope Temp
ABS w/solubles T10 290° N/A 60°
T12 270° 235° 70°
T16 270° 235° 70°
ABS w/BASS T10 290° 270° 60°
T12 270° 265° 70°
T16 270° 265° 70°
ICW T16 73° 75° 43°
E20 T16 170° 220° 60°
ABSi w/BASS T10 260° 265° 60°
T12 260° 265° 70°
T16 260° 265° 70°
ABSi w/solubles T10 260° N/A 60°
T12 260° 235° 70°
T16 260° 235° 70°