®
02MAY01
15
P400/500 Soluble Release User Guide
Step 5: Turn off the Tank
• Turn off the tank by pressing the reset key on the timer or turn off the
main power switch. The heater will turn off automatically when power is
turned off.
Step 6: Disposal of Soluble Solution
• Change the solution whenever half of the P400/500 Soluble Release spool
has been used. You may dispose of the solution by pouring it down the
drain. If you do, you must run tap water from the faucet at the
same time. A 5 to 1 dilution is required to reduce the Ph content
according to typical wastewater standards.
The soluble solution has been specially formulated to be safely
disposed of by standard waste water disposal procedures.
Stratasys cannot anticipate local, state or international regulatory
statutes. Stratasys recommends that disposal procedures be
verified by the proper authorities in your region. Stratasys cannot
be held liable if the solution is not disposed of properly.