Loading...
SUMAVISION EMR Operation Introduction
28 /53
Delete All: Delete all added ports;
Modify in batch: Select several ports to select and modify specific parameters;
Web Network Management Screen
Parameter
Range
Recommended value
System bit rate
0~1000000000
30000000
Output packet length
188/204
188
Destination IP
Unicast IP or multicast IP
Complete according to the
actual situations.
Destination port
1~65535
Complete according to the
actual situations.
TTL
1~255
255
Service
General services / minimum
cost / highest reliability /
maximum throughput /
minimum delay
Complete according to the
actual situations.
Alarm switch
On/Off
On
Output switch
On/Off
On
Refresh: Refresh the screen to acquire current parameters of the device.