SUMAVISION EMR Operation Introduction
27 /53
Web Network Management Screen
Parameter
Range
Recommended value
Number of port added
1~256
Complete according to the
actual situations.
System bit rate
0~1000000000
30000000
Output packet length
188/204
188
Destination IP
Unicast IP or multicast IP
Complete according to the
actual situations.
Destination IP step value
1~
Complete according to the
actual situations.
Destination port
1~65535
Complete according to the
actual situations.
Port No. step value
1~
Complete according to the
actual situations.
TTL
1~255
255
Service
General services / minimum
cost / highest reliability /
maximum throughput /
minimum delay
Complete according to the
actual situations.
Alarm switch
On/Off
On
Output switch
On/Off
On
Delete: Delete the selected port;