5.8 Other special provisions for ATEX:
To be performed weekly or every 100 operating hours:
- Visual control for leaks
- Check the gearbox for unusual running noises and vibrations
- Remove layers of dust on the housing components for ATEX
Every 8000 operating hours – Eccentric bearing have to be replaced.
Every 20,000 operating hours – Rolling bearings on input and output have to be replaced.
Ex
Conditions for installing in an ATEX area
Ambient temperature: -10° . . . +40 ° C
Maximum absolute temperature 90 °C
Installation height < = 1000 m
Maximum input speed 606-621 = 1800 min
-1
Maximum input speed 622-626 = 1200 min
-1
Short term maximum load: 200 % of the rated load torque
Ex
6. Electrical installation
6.1 Safety notes
Installation, connection and commissioning work as well as maintenance and repairs must only be carried out by
qualied experts.
Before any work starts on the motor or the gear motor but particularly before covers are taken o active parts,
the motor must be disconnected as prescribed.
The 5 safety rules as set out in DIN VDE 0105 must be obeyed.
These electric motors comply with the standards and regulations in force and meet the requirements of the Low
Voltage Directive 2014/35/EG.
6.2 Area of application
The motors are completely sealed and air-cooled. Standard protection type: IP 55 with IP 44 brake.
Ambient temperature: -10 °C to +40 °C
Installation height: < 1000 m
The coil is designed to be in insulation class F (150 °C). If operated properly the temperatures on the motor surface
may reach more than 100 °C. Do not touch. Temperature-sensitive parts must not be xed on or rest against it.
The installation is subject to all regulations in force and must be done by qualied personnel.
Ex
When connecting motors via brackets or an IEC ange, a suitable IP65 seal must be provided. The customer is
responsible for tting this seal.
The ventilation openings in the fan hood must not be blocked.
For sucient cooling, the distance between the hood and the wall must not fall below the FB measurement. FA is
the minimum distance required to remove the fan hood.
FA or FB
6.3 Installing the motor