8.1.2 Grease lubrication with top up
CYCLO Drive 6000's that are lled with Esso Unirex N2 must be topped up for the rst time after 500 operating
hours but at least after 2 months. Further top ups in accordance with the table below:
For lubrication quantities (g)when changing when topping up, see paragraph 9.1.
Filling with and changing lubricants:
CYCLO Drive 6000's from size 613 are lubricated in 2 stages and tted with grease nipples for regular topping up.
8.2.1 Type of oil lubrication
8.2.1.1 Horizontal installation position
8.2 Oil lubrication
Top up times
Size 613XDA 613XDB 613XDC 614XDA 614XDB 614XDC 616XDA 616XDB 616XDC 617XDA 617XDB 617XDC
1st stage [g] 25 60 120 25 60 120 60 120 250 60 120 250
2nd stage [g] 450 450 450 450 450 450 750 750 750 1000 1000 1000
Output [g] 300 300 300 300 300 300 300 300 300 500 500 500
Size 618XDA 618XDB 619XDA 619XDB 6205DA 6205DB 6215DA 6215DB 6225DA 6225DB 6235DA 6235DB
1st stage [g] 120 450 330 450 330 450 450 750 450 1000 750 1100
2nd stage [g] 1100 1100 1500 1500 1500 1500 2000 2000 2500 2500 4000 4000
Output [g] 600 600 700 700 700 700 800 800 900 900 1000 1000
Size 6245DA 6245DB 6255DA 6255DB 6265DA - - - - - - -
1st stage [g] 750 1100 1000 1500 1500 - - - - - - -
2nd stage [g] 4500 4500 6000 6000 8000 - - - - - - -
Output [g] 1100 1100 1200 1200 1300 - - - - - - -
X = Means type 0 or 5
Size
Single reduction units
3 5 6 8 11 13 15 17 21 25 29 35 43 51 59 71 87
613X
Oil bath
614X
616X
617X
618X
619X
X = Means type 0 or 5
Size
Single reduction units
11 15 21 29 35 43 59 87
6205
Oil bath
6215
6225
6235
6245
6255
6275
Area Time of lubrication change Notes
Drive and transmission every 2 - 3 years
Under dicult operating conditions the lubrication change
intervals must be reduced.
Output every 3 - 5 years
Operating conditions Time of topping up Notes
up to 10 hours/ day every 3 - 6 months
Under dicult operating conditions the lubrication change
intervals must be reduced.
10 - 24 hours/ day Every 500 - 1,000 hours