Chapter 3 Server Diagnostics 3-33
5. Perform further investigation if needed.
If no faults were detected, the system will boot.
If POST detects a faulty device, the fault is displayed and the fault information is
passed to ALOM CMT for fault handling. Faulty FRUs are identified in fault
messages using the FRU name. For a list of FRU names, see Appendix A.
0:0>IO-Bridge unit 1 jbus perf test
0:0>IO-Bridge unit 1 int init test
0:0>IO-Bridge unit 1 msi init test
0:0>IO-Bridge unit 1 ilu init test
0:0>IO-Bridge unit 1 tlu init test
0:0>IO-Bridge unit 1 lpu init test
0:0>IO-Bridge unit 1 link train port B
0:0>IO-Bridge unit 1 interrupt test
0:0>IO-Bridge unit 1 Config MB bridges
0:0>Config port B, bus 2 dev 0 func 0, tag 5714 BRIDGE
0:0>Config port B, bus 3 dev 8 func 0, tag PCIX BRIDGE
0:0>IO-Bridge unit 1 PCI id test
0:0> INFO:10 count read passed for MB/IOB_PCIEb/BRIDGE! Last read
VID:1166|DID:103
0:0> INFO:10 count read passed for MB/IOB_PCIEb/BRIDGE/GBE! Last read
VID:14e4|DID:1648
0:0> INFO:10 count read passed for MB/IOB_PCIEb/BRIDGE/HBA! Last read
VID:1000|DID:50
0:0>Quick JBI Loopback Block Mem Test
0:0>Quick jbus loopback Test 262144 bytes at 00000000.00600000
0:0>INFO:
0:0> POST Passed all devices.
0:0>POST:Return to VBSC.
0:0>Master set ACK for vbsc runpost command and spin...