EasyManua.ls Logo

Sun Microsystems Sun Fire X4150 - Learning more about Intel NIC Teaming; Completing the Ipmitool Installation; Requirements

Sun Microsystems Sun Fire X4150
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Update the Critical Server-Specific Drivers 61
Learning More About Intel NIC Teaming
For more information on setting up NIC teaming for your environment, refer to the
Intel Connectivity web page on “Advanced Networking Services—Teaming” at:
http://support.intel.com/support/network/sb/CS-009747.htm
Additionally, you may download the complete set of Intel Network Connections
User Guides for your server’s network adapters at:
http://support.intel.com/support/network/sb/cs-009715.htm
Completing the IPMItool Installation
The IPMItool is a command line utility that reads the sensor data repository (SDR)
and displays sensor values, System Event Log (SEL), Field Replaceable Unit (FRU)
inventory information, gets and sets LAN configuration parameters, and performs
chassis power control operations via the server’s service processor (SP). IPMItool is
supplemental software and may be installed using the server’s Tools and Drivers
CD/DVD (described earlier in this chapter).
Once installed, the IPMItool may be used to access your server’s service processor
(or another Sun server’s Service Processor) in the following ways:
Through the server’s ILOM (Integrated Lights Out Manager) or ELOM (Embedded
Lights Out Manager) interface. For details on using ILOM or ELOM, refer to your
server’s documentation.
Through the server’s Windows operating system. To use the IPMItool with
Windows, it must be used in conjunction with the IPMI System Management
driver (available with Windows Server 2003 R2 or R2 SP2, or as a Sun
supplemental software component for Windows Server 2003 SP1). To make sure
you have what you need to use the IPMItool with Windows Server 2003, refer to
the requirements listed below.
Requirements
To use IPMItool, ensure that you have completed the requirements specified for your
Windows Server 2003 version:
For Windows Server 2003 SP1:
Install the IPMI tool as described in “To Install Supplemental Software Using
the Installation Wizard” on page 54.
Install the Sun IPMI System Management driver as described in “To Install
Supplemental Software Using the Installation Wizard” on page 54.

Table of Contents

Other manuals for Sun Microsystems Sun Fire X4150

Related product manuals