Page 16
880 SERIES
7.0 Power Requirements
Sundance
®
hot tubs are designed to provide optimum
performance and exibility of use when connected to their
maximum electrical service. However, they are shipped
factory congured for their most common preferred
electrical connection.
If you prefer, a qualified technician can perform a minor circuit board
modication that allows the hot tub to operate on a different electrical
service (see table below).
7.1 North American 60 Hz Power Options
North American 60 Hz
Voltage 240 VAC 240 VAC 240 VAC
Max. Current Draw:
1-Pump System
2-Pump System
3-Pump System
28A
28A
N/A
39A
39A
39A
N/A
48A
48A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 3 3 3
Circuit Breaker (2-Pole): 40A* 50A** 60A***
*
In the 40A conguration, the heater will not operate while any jets
pump is running. Not recommended for the Maxxus and Aspen.
**
In the 50A conguration, the heater will operate when one jets pump is
running, but will not operate while two jets pumps are running. This is
the factory default setting for 1-pump and 2-pump systems.
***
In the 60A conguration, the heater will operate while two jets pumps
are running, but will not operate if three jets pumps are running.