880 SERIES
18.2 North American 60 Hz Altamar/Cameo/Capri/Marin/Optima
Electrical Wiring Diagram
30A 250VAC
BLOWER
BLOWER
PUMP 2
CIRC PUMP
OZONE
PUMP 1
K12
K9
K15
K14
T1
3
2
TB1
D
C
B
A
J22
240V
MAIN PANEL CONNECTIONS
AV
UV
J43
FUSE PUMP2/AV/UV
5.5 kW HEATER
J51
J4
J49
K11
K10
J59
J44
2A 250VAC
30A 250VAC
FUSE PUMP1
J27
J34
J29
J50
J56
J57
J63
J2
F6
F2
F1
F5
F4
J37
K8
K4
K6
1/4AT 250VAC
WATER
TEMP
SERIAL ADCM
FLOW
HI-LIMIT
TEMP
J16
J17
J18
ON
J1
J9
J11
J13 J14
J15
J10
J24
ZONE 2
J23
ZONE 1
C58
C57
K2
GFCI
TRIP
J8
HEATER
J3
J38
J53
J45
J46
J47
J41
J58
J42
J31
J32
J33
J40
J64
J36
J35
1
2
3
4
S1
FUSE CIRC/OZONE
STATUS
INDICATOR
GRN
J7 J69 J68
WI-FI
(OPTIONAL)
CONTROL
PANEL
FLOW
SENSOR
WATER
SENSOR
BLUEWAVE
STEREO
(OPTIONAL)
CLEARRAY
STEREO POWER
SUPPLY (OPTIONAL)
PUMP 1
1-SPD
CIRC PUMP
HI-LIMIT
SENSOR
STATUS
INDICATOR
LIGHT
SINGLE
SERVICE
STEP LIGHT
(OPTIONAL)
COLOR
LIGHTING
EXPANSION
BLACK
RED
see section 18.3
for dip switch settings
10AT 250VAC
PUMP 2
1-SPD
(IF EQUIPPED)
240 VAC
3-Wire Connection
60 Hz 1-Phase Service
1 pump models: 28A/39A
2 pump models: 28A/39A/48A
DANGER
Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.
!
RISK OF SHOCK OR
ELECTROCUTION!
18.3 Dip Switch Settings
The dip switches are at the S1 location on the board.
A. Switch settings for Domestic 60Hz Models
BREAKER
DIP SWITCH NUMBER
1 2 3 4 5 6 7 8 9 10
40A OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
50A* OFF OFF ON OFF OFF OFF OFF OFF OFF OFF
60A** OFF OFF OFF ON OFF OFF OFF OFF OFF OFF
*50A is the factory default setting for 1- and 2-pump models
**60A is the factory default setting for 3-pump models
DOMESTIC DIP SWITCH SETTINGS
S1 LOCATION
40A 50A 60A
1
2
3
4
5
6
7
8
9
10
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ONOFF
1
2
3
4
5
6
7
8
9
10
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ONOFF
1
2
3
4
5
6
7
8
9
10
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ONOFF
880 1- and 2-pump
Service Jumper Wiring
Wire From To
1 J37 J36
2 J51 J46
3 J59 J41
4 J44 J49 & J35
5 J33 J47
6 J4 J58
7 J3 J45
880 Maxxus and Aspen
Service Jumper Wiring
Wire From To
1 J37 J36
2 J51 J46
3 J59 J41
4 J44 J49 & J35
5 J33 J47
6 J61 J45
7 J65 J40
8 J4 J58
9 J3 J32

Table of Contents

Other manuals for Sundance Spas Maxxus

Related product manuals