9. Ensurethattheprogramswitchlocatedonthelowerleft
sideofthecircuitboardisinthe“up”positionandthat
the redLEDlocatednexttoitisOFF.
10. Ifthereisstillnoproductdispensed,calltheSureShot
DispensingSystems®TechnicalAssistanceCenterat
18887779990or19028659602.
Thedispenserisnot
dispensingtheproper
amountofproduct
1. Wrongdairyproductisbeingdispensed–forexample,
skimisinthecreamslot.Reviewhowthedispenser
operates.
2. Checktoensurethatthesystemisresetproperly.See
page27.
3. Makesurethattheproductdeliverytubeisinsertedin
thevalvecorrectlysinceincorrectplacementcanaffect
productdelivery.Seepage8.
4. Checktoensurethatvalveandvalveareaareclean.
5. Makesurethevalvedoorisnotbeingopenedbefore
theproductbagortankisempty.
6. Makesureproducttanksarefilledtotherequiredlevel.
7. Checktoseeiftherefrigerationunitistoocoldortoo
warm.Icemayinterferewithproductflow.Checkthe
temperatureoftheproducttoensurethatitis
approximately38ºFor3.3ºC.
Note: Temp eratureaffectstheflowofcreamandsome
otherliquids.Icemayinterferewithflow.
8. Checktherefrigerationtemperature. Icemayaffect
productflow. Toadjusttemperature,seepage25.
9. Checktoensurethesystemisresettingproperly.The
volumestobedispensedarepresetelectronicallyin
ourfactoryandareresettothespecifiedamounts
automaticallyeachtimethefrontvalvedoo risopened.
Ifyourdispenserdoesnothavearesetbutton(See
page4),followthisproceduretochecktoensurethe
dispenserisresetting:
a. makesurenoproductisspilledduringthetestby
pinch ingofftheproductdeliverytubewithapinch
cliporforkbeforeyoubegin.
b. openthevalvedoorbyunscrewingtheknobina
counterclockwisemotion.
c. TR1,TR2,TR3willbedisplayedintheLCDwhen
thevalvedoorisopened.Anewbagofproduct
mustbeloadedtoensurepropervolumesofproduct
aredelivered.
NOTE:Ifthe displaydoesnotshowTR1,TR2,orTR3when
thevalvedoorisopened,thereedswitchis
defectiveandmustbereplaced.Callthe Sure Shot
DispensingSystems®TechnicalAssistanceCenter
at18887779990or19028659602for
assistance.
d. ensuretheproductdeliverytubeisinsertedproperly
inthevalvedoor.
e. closethevalvedoorsecurely,byreplacingtheknob
screw. Donotovertightenthescrew.

Table of Contents