EasyManua.ls Logo

SureShot IntelliShot - Troubleshooting: Exterior Warmth and Valve Issues; Exterior Warmth and Valve Door Problems

SureShot IntelliShot
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
f. removethepinchcliporfork.
g. pushadispensebuttononthefrontdoor.Ifproduct
isdispensed,themachinehasresetandisworking
properly.Ifproductisnotdispensed,callthe
SureShot DispensingSystems®Technical
AssistanceCenterat18887779990or
19028659602forassistance.
10. Ifyourdispenserhasaresetbutton,followthereset
procedureonpage12.
Valveissticky 1. Astickyvalveisusuallycausedbyproductbuildupon
thevalve.Theproblemiscorrected bycleaningthe
valve.SeeInstructionsonpages20,21.
2. Ifthisdoesn'tcorrecttheproblem,calltheSureShot
DispensingSystems®TechnicalAssistanceCenterat
18887779990or19028659602.
Valvedoorisbroken Thisindicatesthedoorhingeisbroken.Thehingeisintwo
parts:hooks,pins.
1. Hooks:Ifeitherorbothoftheplastic“hooked”areasof
the hingearemissing,thedoorsectionvalveassemblyis
brokenandmustbereplaced.ContactSureShot
DispensingSystems®TechnicalAssistanceCenterat
18887779990or19028659602forreplacements.
2. Pins:Ifeitherorbothplastic“pins”aremissingfromthe
hingearea,thebodysectionofthevalveisbrokenand
mustbereplaced.ContactSureShot Dispensing
Systems®TechnicalAssistanceCenterat
18887779990or19028659602forreplacements.
Dispenserisunusually
warmontheexterior
1. Makesureanyventsatthetopandbackofthe
dispenserarenotblocked.
2. Makesurethedispenserisnottooclosetoaheat
generatingmachine,suchasacoffeemaker.Allow
minimum1inchairspacebetweenmachinesatall
times.
3. Makesurethedispenserislevelonthecountertop.
4. Makesurethecondenserisnotdirty. Removetheback
paneltoexaminethecondenser.Ifitisdustyordirty,
useavacuumtocleanit.
5. Makesurethefanisoperating.Removethefrontpanel
andobservethefanontherightsideofthedispenser,in
frontofthecompressorandbehindthecircuitboard.
(Seepage24)Doavisualinspectiononly.Becareful
nottoinjurefingersbystickingtheminthefan. Ifthe
fanisnotrunning,callSureShot DispensingSystems®
TechnicalAssistanceCenterat18887779990or
19028659602forservice.

Table of Contents