ER-40
ER-41
ER-43
ER-44
ER-45
ER-50
ER-51
ER-52
ER-100
ER-101
Battery temperature sensor error
Battery discharge MOS error
Battery charge MOS error
MCU MOS error
MCU over current protection
11.5
11.6
Troubleshooting Troubleshooting
ER-104
ER-105
ER-106
ER-107
ER-108
ER-109
ER-110
ER-111
ER-113
ER-114
Startup self-diagnostic
temperature sensor error
Contact manufacturer
or Authorized Surron Dealer
Contact manufacturer
or Authorized Surron Dealer
Contact manufacturer
or Authorized Surron Dealer
Contact manufacturer
or Authorized Surron Dealer
Stop using the bike and wait until the MCU
temperature back to working condition
Bike enters Low Power Mode
Stop using the bike and wait until the Motor
temperature back to working condition
Check if motor is in locked rotor condition
Contact manufacturer
or Authorized Surron Dealer
Contact manufacturer
or Authorized Surron Dealer
Main power cable instant
Low voltage protection
Main power cable
Low voltage protection (level 3)
Main power cable high voltage protection
Battery cell over/low
temperature protection (level 3)
Throttle signal protection
Check MCU main power cable
Charging the battery pack
Disable REGEN function
Check if throttle cable is short circuited
or unable back to idle position
Stop using the bike and wait until the
temperature back to working condition
Contact manufacturer
or Authorized Surron Dealer
Battery discharge MOS over
temperature protection
Battery discharge connector over
temperature warning
Battery discharge connector over temperature
protection(battery protection triggered)
Battery discharge connector
temperature sensor error
Stop using the motorcycle and wait until the discharge
connector temperature back to working condition,
check the contact area of the connector
Stop using the motorcycle and wait until the discharge
connector temperature back to working condition,
contact manufacturer or Authorized Surron Dealer
Stop using the motorcycle and wait until the discharge
connector temperature back to working condition,
check the contact area of the connector
Stop using the motorcycle and wait until the battery
temperature back to working condition
or contact manufacturer or Authorized Surron Dealer
Motor position sensor error
Motor locked rotor error
MCU current sensor error
MCU over temperature protection
Motor over temperature protection