11.7
11.8
Troubleshooting Troubleshooting
ER-115
AL-116
AL-117
AL-118
AL-119
AL-120
AL-121
AL-122
AL-123
AL-124
AL-125
AL-126
ER-127
AL-128
ER-129
ER-130
ER-131
ER-133
ER-134
ER-135
Motor temperature sensor error
REGEN disabled
CAN communication error
Speed sensor error
Check battery temperature and battery voltage
Check all wire and cables
Battery cell high voltage difference
protection
Contact manufacturer or
Authorized Surron Dealer
Check if front and rear wheel
speed sensor is well connected
Disable REGEN function
Main power cable instant High voltage
protection
Key switch power loose protection
MCU firmware malfunction protection
Contact manufacturer or
Authorized Surron Dealer
Hyper Bee Remote
emergency power off protection
Magnetic switch protection
Tilt switch protection
Main power cable Low power protection
Check if throttle cable is short circuited,
cable damaged or broken
Check bike communication cables,
charge the battery pack
Check the condition of the Hyper Bee Remote button
or turn o the key switch and back to ON again
Check magnetic switch and magnetic switch circuit
Re-ready the bike or turn off the tilt switch
function in setting mode
Throttle ground protection
Check key switch and MCU cable connection
Turn OFF the key switch and back to ON again
Battery SOC low or high temperature
power limitation (level 2)
Stop using the motorcycle and wait until the battery
temperature back to working condition
and charge the battery pack
Battery cell discharge low or high
temperature power limitation (level 2)
Main power cable Low voltage
power limitation (level 1)
Battery SOC low or high temperature
power limitation (level 1)
Battery cell discharge low or high
temperature power limitation (level 1)
MCU over temperature power limitation (level 1)
Motor over temperature power limitation (level 1)
Stop using the motorcycle and wait until the battery
temperature back to working condition
Charge the battery pack
Stop using the motorcycle and wait until the Motor
temperature back to working condition
Stop using the motorcycle and wait until the battery
temperature back to working condition
and charge the battery pack
Stop using the motorcycle and wait until the battery
temperature back to working condition
Stop using the motorcycle and wait until the MCU
temperature back to working condition