95
1. Turn the engine off and allow it to cool.
2. Remove the motor cover.
3. Remove the rear panel bolts and rear panel
1.
4. Disconnect the PTT cables from the clamp
2. Remove the side cover bolts and star-
board side cover 3.
5. Turn the boat handle to the left so that the
outboard motor’s rudder angle becomes the
largest.
6. Inject approximately 10 grams of grease at
initial 20 hours.
Inject approximately 5 grams of grease at
every 100 hours (12 months).
NOTE:
If grease will not inject into the fitting, consult
your Authorized Suzuki Marine Dealer.
Your authorized Suzuki Marine Dealer may also
have additional recommendations due to
regional climate or operating conditions.
Please consult him for advice.
NOTICE
Using a hydraulic or air powered grease
gun to service the grease nipple
A
on the
mount oil seal cover may cause damage
to the oil seal.
Do not use powered grease guns when
servicing grease nipple
A
on the mount
oil seal cover.