5120A/5115A Operations and Maintenance Manual 67
7.3 The Network Data Port
The network data port outputs phase difference data while the test set is in the Collecting state. The
phase differences are in units of cycles of the Input signal. Phase differences are output as floating
point numbers, one number per line, either 1, 10, 100, or 1000 samples each second. The default
rate is 1000 samples per second, to change the rate use the set phaserate command. See Chapter
7, Setting Data Port Output Rate” on page 65.
set print local Print new jobs to local (USB) printer.
set print remote <host> <port> Print new jobs to network printer.
set referencefreq <auto|freq> Selects automatic, or specified manual reference frequency used
by frequency counter.
set tau0 <tau0value> Sets tau0 value in seconds: 0.001, 0.01, 0.1 or 1
set timeconstant <value> Sets length of running average time constant for spectrum and
Allan deviation
set timeformat <24/12> Selects time format for printout time stamps.
set title <title> Sets user specified title (quoted string up to 34 characters)
show adev Returns snapshot of Allan deviation tables.
show date Returns current date and time in selected format.
show dateformat Returns selected printout date stamp format.
show fcounter Returns snapshot of frequency counter table.
show freqdiff Returns snapshot of frequency difference strip chart.
show inputs Returns input frequency and amplitude on input signal ports.
show ipn Returns integrated phase noise table.
show mac Returns MAC (ethernet) address of the test set.
show phasediff Returns snapshot of phase difference strip chart.
show phaserate Returns current phaserate value.
show printformats Returns acceptable values for set print format command.
show printoptions Returns current printer settings.
show screens Returns name of screens that can be printed.
show spectrum Returns snapshot of spectrum table.
show spurs Returns snapshot of spur table.
show state Returns current collecting state.
show tau0 Returns current tau0 value.
show timeformat Returns selected printout time stamp format.
show title Returns current user specified title.
show version Returns model, software and hardware version information.
start Begin data collection
stop Stop data collection.
Table 4: Command Summary
Command Synopsis

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom 5120A and is the answer not in the manual?

Symmetricom 5120A Specifications

General IconGeneral
BrandSymmetricom
Model5120A
CategoryRecording Equipment
LanguageEnglish