097-10603-01 Rev. A – November 2004 X72 Desiger’s Reference and User’s Guide 85
Flywheeling Recovery – Normal
Flywheeling Recovery – Normal
Figure D-3 Flywheeling Recover with 1PPS offset < 1µsec
In this test the X72 was synchronized to 1PPS before this data set. Antenna is
removed at hour 0 and reapplied at approximately hour 12.5. The X72 1PPS output
signal had reached an offset of 220 nanoseconds.
The subsequent frequency change is what returns the 1PPS offset to 0
nanoseconds.