T-K3 Service Manual
Ver. 1.05
34
CONFI DENTIAL
Error Code
Checkpoint
Check the dipswitch settings on PCB
Warning for the "991" error code
(Refer to section 12-3)
Checkpoint
1 Check if there is any blockage in the air inlet of the unit.
2 Check if there is any blockage along the exhaust run.
3 Check the manifold pressure in the T-K3.
Checkpoint
1 Check
as su
l
and
ressu re (Refer to section 1)
2
Check the i
niter
Refer to section 10-18
①
Cracks/soot on igniter rod
②
Improper gap between burner & igniter rod
Normal gap: 0.16"
③
PCB fault
Normal: AC 90
~
110V at #7
ur
le-
ur
le
④
Igniter fault
3 PCB fault
①
No voltage to main gas solenoid valve (MV) C
Normal: DC78
~
100V between COM
blue
& #3
li
ht blue
②
No volta
e to
as solenoid valve
S
1
Normal: DC78
~
100V between COM
blue
& #9
ree n
③
No volta
e to
as
ro
ortional valve
VG
0
H1
Normal: DC1
~
15V between white & red
4 Gas solenoid valve fault
①
Main gas solenoid valve (MV) fault C
Normal: 0.9
~
1.3k
Ω
between COM
blue
& #3
li
ht blue
②
Gas solenoid valve
SV
1
fault
Normal: 1.3
~
1.9k
Ω
between COM
blue
& #9
reen
③
Gas
ro
ortional valve
VG
0
fault H1
Normal: DC1
~
15V between white & red
5 Disconnected/dama
ed O.H.C.F. C2
Visual inspection:connection/breakage of wires.
Normal: 1
Ω
or less between blue & blue
031
Error Code Malfunction description Cancellation method
Malfunction description Cancellation method
Dipswitch setting fault
Turn off the power or water
supply
Dia
nosis
On the PCB, press the INC and
DEC buttons simultaneously for 3
sec. Then turn the power off.
Diagnosis
Error Code Malfunction descri
tion Cancellation method
101
Ignition failure
Turn off the power or water
supply
Diagnosis
111
Error code is
shown after
three failed
attempts at
ignition
B2
Visual inspection: connection/breakage of wires and/or
observed weak spark.
(Refer to section 10-13)