T-K3 Service Manual
Ver. 1.05
35
CONFI DENTIAL
Checkpoint
6C1
Normal:1
Ω
or less between blue & blue
7 Inspect flame rod I
①
Check for any soot on the rod.
②
(in this case, the wire is contacted to the manifold surface.)
③
PCB fault
④
Flame rod fault (insulated resistance)
Normal: 40KHz
~
60KHz
between oran
e &
reen
8 Check if hi-limit switch is properly functioning.
Checkpoint
1 Check gas supply and pressure (Refer to section 1)
2 PCB fault
①
No voltage to gas main solenoid valve (MV) C
Normal: DC78
~
100V between COM
blue
& #3
li
ht blue
②
No volta
e to
as solenoid valve
SV
1
③
No volta
e to
as
ro
ortional valve
VG
0
H1
Normal: DC1
~
15V between white & red
3 Gas solen oid fault
①
Main gas solenoid valve (MV) fault C
Normal: 0.9
~
1.3k
Ω
between COM
blue
& #3
li
ht blue
②
Gas solenoid valve
SV
1
fault
Normal: 0.9
~
1.9k
Ω
between COM
blue
& #9
reen
③
Gas
ro
ortional valve
VG
0
fault H1
Normal: DC1
~
15V between white & red
4 Check for soot on the flame rod I
①
Clean the flame rod
②
PCB fault
③
Flame rod fault (insulated resistance)
Normal: 40KHz
~
60KHz
oran
e &
reen
Error code is
shown after
three failed
attempts at
ignition
Check the connection of ground wire; make sure there is firm
contact to the
round of the T-K3
During operation: more than 1μA through the flame rod wire
(orange)
Error Code Malfunction description Cancellation method
Error Code Diagnosis
111
Visual ins
ection: connection/breaka
e of wires.
Disconnected/dama
ed hi-limit switch.
(Refer to section 10-12)
Flame blows out
Turn off the power or water
su
l
Diagnosis
Error code is
shown after
three failed
attempts at
ignition
Normal: DC78
~
100V between COM (blue) & #9 (green)
121
During operation: more than 1μA through the flame rod wire
(orange)