199
OPTIONS
Travel Alarm
An alarm is sounded when the machine
travels and stops when traveling is stopped.
If the alarm does not sound when the
machine travels, the fuse may be blown.
Inspect the fuse.
WARNING
If the fuse which has just been replaced
should blow again, there is a problem in
the electrical system. This could cause
fires. Contact a Takeuchi dealer.
1. Park the machine in a safe place.
2. Set the starter switch to “OFF”.
3. Open the fuse holder and inspect for blown
fuses.
4. If a fuse is blown, replace it with a spare
fuse of the same capacity.
C4B029
1
E4J007
NormalBlown
Fuse Layout and Circuits Protected
Capacity Protected circuit
30A Stop solenoid
10A Lever lock
10A Second travel speed
20A Lights, Tail lamp
15A Heater, Radio
10A Feed pump, Instrument panel
25A External power socket,
Cigarette lighter,
Wiper (cab),
Travel alarm
10A
Horn, Clock(radio), Interior light