MAINTENANCE
Every 50 Hours
2. Use the grease gun to insert grease
through the grease nipple
in
the grease
discharge valve
(1).
3.
Check the track tension.
Decreasing the tension
1 . Remove the cover.
2.
Use the wrench to slowly loosen the
grease discharge valve
(1)
and drain the
grease.
If the grease does not drain easily, move
the machine forward or rearward.
3.
Tighten the grease discharge valve
(1).
Tightening torque: 59 N·m (43.4 ft-lb.)