CONTROLS
Switches
Ignition Switch
OFF
PREHEAT
ON
J28009E
IMPORTANT:
Do
not repeatedly switch
the key from OFF to ON and ON to OFF
over a short period. Doing
so
will cause
engine breakdown.
PREHEAT
....... Position for preheating the
engine.
OFF
...
...
..
........ Position for stopping the
engine and inserting
and
removing the
key.
ON
...
.....
...
.
......
Position
in
which the engine
is
running.
In
this position,
all
the electrical equipment
is
functional.
START
..
...
.
......
Position for starting the
engine. When the
key
is
released, the switch
automatically returns to the
ON
position.
Horn Button
CJ
Press
the right button
on
the right control
lever to blow the horn.
56
Float Button
.A,
WARNING
• Make sure the bucket
is
lowered to
the ground before putting the lift arms
in
the Float mode. Putting the lift arms
in
the Float mode while they are raised
will cause the bucket to
fall
and
is
extremely dangerous.
•
Do
not drive the loader forward with
the lift arms
in
the Float mode.
This button sets the lift arms to the Float
mode. The lift arms
are
put to the Float
mode while this button
is
pressed
in.
When
the button
is
released, the Float mode
is
canceled.
Setting the arm float to the detent mode
To
set to the detent mode, press and hold the
arm
float button
and
move the right control
lever forward once.
To
turn off the detent
mode,
move the right control lever rearward.
T8B0091
When
in
the Float mode, the bucket
can
follow the contour of the ground without
movement of the control lever.