Tandy 1000
3-3-1.
Function
of
Test
Points
Technical Reference Manual
Twelve
test
points
(two
for
ground)
are
equipped
on
the
PCBA
MFD
control
for
the
check
and
adjustment
of
the
FDD.
(1)
TPI
(Track
00
sensor)
Test
point
to
observe
the
output
of
the
track
00
detection
photo-
transistor
(shumitt
inverter
included).
As
well
as
TRACK
00
output
signal,
TPI
becomes
LOW
level
when
the
head
is
on
track
00
or
around
track
00
position.
TPI
(Track
00
sensor)
Track
02--i
(TTL
level)
~TraCk
00
(Fig.312)
Typical
waveform
of
TPI
Note:
The
TRACK
00
output
signal
goes
TRUE
(LOW
level)
only
when
the
phase
A
coil
of
the
stepper
motor
is
energized
and
the
direction
latch
is
set
to
the
step-out
direction
(refer
to
Fig.310).
Therefore,
the
level
change
timing
of
the
TRACK
00
signal
is
not
consistent
with
that
of
the
TPI
signal.
(2)
TP2
(Erase
gate)
Test
point
to
observe
the
output
of
the
erase
gate.
When
TP2
is
HIGH
level,
erase
current
flows
through
the
erase
head.
This
TP
is
used
for
the
check
and
adjustment
of
the
required
delay
time
of
the
erase
gate
signal
against
the
WRITE
GATE
input
signal
when
the
tunnel
erase
head
is
used.
-
322
-

Table of Contents

Other manuals for Tandy 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tandy 1000 and is the answer not in the manual?

Tandy 1000 Specifications

General IconGeneral
ProcessorIntel 8088
Processor Speed4.77 MHz
RAM128 KB (expandable to 640 KB)
Operating SystemMS-DOS 2.11
ManufacturerTandy Corporation
Release Year1984
StorageSingle or double 5.25" floppy disk drive (360 KB), optional hard drive
SoundTandy 3-voice sound
PortsParallel, Serial
GraphicsCGA (Color Graphics Adapter)
Graphics Modes320x200, 640x200