96
Model C606Operating Procedures
Step 17
Inspect the duckbill valve for proper installation
inside the syrup nose fitting. The tip of the duckbill
valve must be flat to seal the syrup line.
(See Figure 182.)
Figure 241
If the tip is not flat, remove the syrup nose fitting and
remove/reinstall the duckbill valve. Using a shake
cup filled with sanitizing solution, rinse the syrup
nose fitting to wet the bottom of the duckbill valve.
Reinstall the syrup nose fitting onto the syrup line
fitting. If the tip will not remain flat when the syrup
fitting is assembled, replace the duckbill valve.
Step 18
Install the o-ring on the syrup nose fitting.
Step 19
Repeat steps 3 -18 for all syrup flavors.
Step 20
Remove the pick up tubes from the pail of sanitizing
solution and allow them to drain.
Step 21
Place all the pick up tubes into the syrup containers.
Ensure the syrup lines match their respective
flavors.
For Syrup Bag System: Attach the bag connector
fitting to the proper syrup flavor.
Step 22
Select the CALIBRATION symbol
on the control
panel to display the menu options.
Step 23
Touch the AUTO symbol
to move the arrow to
SYRUP PRIME. Touch the CALIBRATION symbol
again to display the Syrup Prime screen.
Step 24
Select the FLAVOR SELECT symbol
for the
corresponding syrup valve to start the flow of syrup.
Step 25
Allow the syrup to flow until all of the sanitizing
solution and air is purged from the line.
Step 26
Touch the FLAVOR SELECT symbol
to stop the
flow of syrup.
Step 27
Lubricate the o-ring on the syrup nose fitting. Install
the syrup valve into the shake door. Secure the
valve by lowering the retainer.
Step 28
Repeat steps 20 - 27 for all syrup flavors.
Step 29
Clean the syrup cabinet interior with a clean,
sanitized towel. Spray resistant areas with the
sanitizing solution.