Model C606 Operating Procedures
050112
Step 3
Raise the retainer and remove the syrup valve from
the freezer door. Place the valve in a pail located
under the draw valve.
Step 4
Select the CALIBRATION symbol
on the control
panel to display the menu options.
Step 5
Touch the AUTO symbol
to move the arrow to
SYRUP PRIME. Touch the CALIBRATION symbol
again to display the SYRUP PRIME screen.
Step 6
Select the FLAVOR SELECT symbol
for the
corresponding syrup valve to start the flow of
cleaning solution through the syrup line.
Step 7
Allow the cleaning solution to flow until all the syrup
is flushed from the line.
Step 8
Touch the FLAVOR SELECT symbol
to stop the
flow of cleaning solution.
Step 9
Repeat steps 2 - 8 using an approved 100 PPM
sanitizing solution (examples: Kay-5® or
Stera-Sheen®). USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 10
Remove the syrup nose fitting from the syrup valve
by turning the cap counter-clockwise.
Step 11
Remove the duckbill valve and the o-ring from the
syrup nose fitting.
Step 12
Using the white end of the double-ended brush,
scrub the inside of the syrup nose fitting and the
syrup line fitting to remove any residual particles.
Step 13
Using a shake cup filled with an approved 100 PPM
sanitizing solution, rinse the syrup valve fitting
thoroughly.
Step 14
Using a clean, sanitized towel, gently wipe any syrup
from the duckbill valve.
Step 15
Install the duckbill valve into the syrup nose fitting,
with the flat end aligned with the open slot in the
syrup nose fitting.
Note: Replace the duckbill valve if it is damaged or
extends past the syrup nose fitting slot.
(See Figure 181.)
Figure 240
Step 16
Install the syrup nose fitting onto the syrup line
fitting. Tighten by hand until snug.
Note: The duckbill valve must be wet when the
syrup nose fitting is assembled on the syrup line
fitting. The sanitized water will lubricate the bottom
flat surface and prevent the duckbill from twisting
when the the syrup nose fitting is tightened.