Taylor C606 - Control Panel and Draw Valve Troubleshooting

Taylor C606
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100
Troubleshooting Guide Model C606
PROBLEM PAGE
REF.
REMEDYEITHER SIDE
PROBABLE CAUSE
SOFT SERVE SIDE
PROBABLE CAUSE
SHAKE SIDE
PROBABLE CAUSE
1. Soft lock
message
appears on
display.
(Continued)
e. Mix out condition. e. The level of mix in the mix
hopper must be up to the
fill level indicator on the
agitator paddle. The
freezer must now be
disassembled and brush
cleaned, or placed in a
heat cycle.
36
f. The agitator is not
installed.
f. The agitator must be
cleaned and installed
before starting the HEAT
cycle. The freezer must
now be disassembled and
brush cleaned or placed in
a heat cycle.
69 /
72
2. Hard lock
message
appears on
display.
a. Brush clean interval
exceeded.
a. The freezer must be
disassembled and brush
cleaned within 24 hours
when the counter
indicates one day
remaining.
35
b. A barrel or hopper
thermistor is faulty.
b. Call an authorized service
technician.
---