Loading...
109
Model C606
Troubleshooting Guide
PROBLEM PAGE
REF.
REMEDYEITHER SIDE
PROBABLE CAUSE
SOFT SERVE SIDE
PROBABLE CAUSE
SHAKE SIDE
PROBABLE CAUSE
21. Syrup cannot
be calibrated
or has
inconsistent
calibration
readings.
(Continued)
h. The syrup line is
plugged or restricted.
h. Flush and sanitize the
syrup lines. Clean the
syrup system weekly. Do
not attach the short syrup
line to the door when the
line is not primed with
syrup.
94
i. Air in syrup line. i. Follow syrup line priming
procedure to remove air
from line.
80
j. Air intake line to
pump will not hold
syrup prime.
j. Lubricate pump tube
fitting o-rings. Inspect the
intake line for leaks.
94
22. Syrup
continues to
flow after
drawing a
shake.
a. Air in syrup line. a. Follow syrup prime
procedure.
80
b. Duckbill valve
damaged.
b. Remove syrup nose fitting
and clean. Replace
duckbill valve.
95
23. Spinner shaft
will not rotate
to blend mix
and syrup.
a. Flexible coupling is
broken.
a. Call an authorized service
technician.
---
b. Pin is missing in
quick disconnect of
spinner coupling.
b. Call an authorized service
technician.
---
c. Spinner motor is out
on thermal overload.
c. Allow the spinner motor to
cool. Check lubrication on
the spinner shaft.
53