EasyManua.ls Logo

Taylor C606 - Page 114

Taylor C606
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
108
Troubleshooting Guide Model C606
PROBLEM PAGE
REF.
REMEDYEITHER SIDE
PROBABLE CAUSE
SOFT SERVE SIDE
PROBABLE CAUSE
SHAKE SIDE
PROBABLE CAUSE
20. The mix
pump runs
constantly in
the AUTO
mode.
a. Draw valve is not
fully closed.
a. Raise draw handle so
draw valve is closed all
the way.
68
21. Syrup cannot
be calibrated
or
inconsistent
calibration
readings.
a. The pump tube has
collapsed.
a. Replace pump tube.
93
b. Syrup temperature
too cold.
b. Allow the syrup to warm
up before using.
Note: Never refrigerate
the syrup. Keep a
replacement container
near the shake machine
location so the syrup
temperature can stabilize
before use.
80
c. Thick syrup in bottom
of container.
c. Shake well before use.
80
d. Syrup leak. d. Inspect syrup system for
leaks.
---
e. Syrup lines are not
matched with the
syrup flavor or are
not properly
connected.
e. Match the color of the
syrup pick-up tube and
cap with the correct syrup
container. Make sure the
tube is properly
connected.
96
f. Plugged syrup line
fitting at freezer door
connection.
f. Clean the syrup line
fitting.
80
g. The pick-up tube is
pinched or kinked.
g. Adjust the line routing so
that it is not pinched or
kinked.
80

Table of Contents