107
Model C606
Troubleshooting Guide
PROBLEM PAGE
REF.
REMEDYEITHER SIDE
PROBABLE CAUSE
SOFT SERVE SIDE
PROBABLE CAUSE
SHAKE SIDE
PROBABLE CAUSE
18. The draw
valve is not
closing.
a. The draw valve was
not aligned with the
actuator bracket
when the freezer
door was installed.
a. Reassemble with the
correct alignment. Tighten
the handscrews in a
criss-cross pattern when
installing the freezer door.
55
b. The draw valve was
not lubricated.
b. Lubricate the draw valve
and o'rings.
53
c. The spinner shaft
was not lubricated.
c. Lubricate the spinner
shaft.
53
d. The spinner blade
became disengaged
from the driven
spinner when the
draw valve was
raised.
d. Call an authorized service
technician to check the
spinner coupling position
on the motor.
---
e. The product is too
thick.
e. Check that the product
temperature is within
specification. (See
problem “Product Too
Thick” on page 102.)
---
f. The shake actuator
assembly is out of
alignment or is
malfunctioning.
f. Call an authorized service
technician.
---
19. The mix
pump will not
operate in the
PUMP mode.
a. Pump motor is not
running.
a. Push the pump reset
button.
32