106
Troubleshooting Guide Model C606
PROBLEM PAGE
REF.
REMEDYEITHER SIDE
PROBABLE CAUSE
SOFT SERVE SIDE
PROBABLE CAUSE
SHAKE SIDE
PROBABLE CAUSE
16. No control
panel
functions with
power switch
ON.
a. Machine is
unplugged.
a. Plug into wall receptacle.
---
b. Circuit breaker OFF
or blown fuse.
b. Turn the breaker ON or
replace the fuse.
---
17. The draw
valve is not
opening.
a. The power switch is
off.
a. Place the power switch in
the ON position.
36
b.Theshakesideisin
the STANDBY mode.
b. Cancel the STANDBY
mode.
43
c. A heat cycle is in
progress.
c. Wait for the completion of
the heat treatment cycle.
35
d. The menu is
displayed, making
the flavor select keys
inoperative.
d. Exit the menu by moving
thecursorarrowto“EXIT
and touching the CAL
symbol. This will restore
the control keys to their
normal function.
78
e. The draw valve
wasn't aligned with
the actuator bracket
when the freezer
door was installed.
e. Reassemble with the
correct alignment. Tighten
the handscrews in a
criss-cross pattern when
installing the freezer door.
55
f. The draw valve was
not lubricated.
f. Lubricate the draw valve
and o'rings.
53
g. The shake actuator
assembly is out of
alignment or is
malfunctioning.
g. Call an authorized service
technician.
---