55
Model C606 Operating Procedures
Step 12
Place the freezer door o-ring into the groove on the
back of the freezer door. Lubricate the outside
diameter of the front bearing. Slide the front bearing
into the door hub.
Note: If necessary, put two small spots of lubricant
at the 10 o'clock and 2 o'clock positions on the
upper portion of the freezer door o-ring to keep it in
place.
Figure 113
Step 13
Install the shake freezer door. Position the freezer
door on the four studs on the front of the freezing
cylinder. Align the top of the draw valve with the
actuator bracket. Install the handscrews (short
handscrews at the bottom of the door). Tighten
equally in a criss-cross pattern to insure the door is
snug. Do not over-tighten.
Figure 114
Step 14
Lubricate the shaft of the spinner blade up to the
groove. (See Figure 115.)
Figure 115
Step 15
Insert the spinner blade shaft into the center of the
driven spinner, and through the draw valve cavity
until the shaft appears at the top of the draw valve.
The spinner blade must be aligned and engaged to
the driven spinner at the bottom. This allows the
spinner shaft to raise high enough to be engaged
into the spinner coupling at the top. (See
Figure 116.)
Figure 116