80
Model C606Operating Procedures
Step 7
Exit the CALIBRATION mode by touching the
CALIBRATION symbol
. A blank screen will
appear and the AUTO symbol
and the
OPTIONAL FLAVOR symbol will return to their
normal function.
Note: Whenever a particular syrup line is not used,
the syrup hole plug found in the spare parts kit must
be installed. Place the syrup hole plug o-ring into the
groove of the syrup hole plug, and lubricate. Install
the hole plug in the door. Lower the retaining pin to
secure the plug in place.
Syrup Priming Procedure
The purpose of priming the syrup line is to eliminate
any air in the syrup delivery syst em. Air in the syrup
line can cause irregular shake blending, flavor
carry-over, and syrup leaking from the door spout
after the draw valve has closed. Each time a syrup
container is drained or replaced, prime the syrup
system until all the air has been removed and the
syrup flow is uniform.
Step 1
Retrieve a full syrup container from the dry storage
area.
Step 2
Shake the syrup container prior to opening it. Open
the full syrup container.
Step 3
Pull the feed tube from the empty syrup container
and clean the outside of the feed tube with a clean,
sanitized towel.
For Syrup Bag System: Disconnect the empty bag
and clean the hose connector fitting with a clean,
sanitized towel. Attach the hose connector fitting to
a full bag of syrup. Place the bag on the shelf in the
syrup compartment. Make sure the hose is not
pinched and there are no kinks in the tubing.
Step 4
Place the feed tube into the full syrup container and
replace the syrup container in the syrup cabinet.
Step 5
Dispose of the empty syrup container.
Step 6
Prime the syrup line by removing the syrup valve
from the freezer and hold it over an empty cup.
Step 7
Touch the CALIBRATION symbol
to display the
menu options. The CALIBRATION symbol
,the
AUTO symbol
on the shake side, and the
OPTIONAL FLAVOR symbol
will be illuminated.
Note: The screen will display the calibration menu
options. (See Figure 198.)
UNFLAVORED DRAW
SYRUP CALIBRATION
SYRUP PRIME
> EXIT
Figure 198
Step 8
Touch the AUTO symbol
or the
OPTIONAL FLAVOR symbol
to scroll the arrow
to SYRUP PRIME. (See Figure 199.)
UNFLAVORED DRAW
SYRUP CALIBRATION
> SYRUP PRIME
EXIT
Figure 199
Step 9
Touch the CALIBRATION symbol
to enter the
SYRUP PRIME mode. (See Figure 200.)
SYRUP PRIME
Select a Flavor
< Press to clear
Figure 200