51
8. Remove the seal o-ring from the seal.
(See Figure 72.)
Figure 72
9. Remove the discharge tube lock nut by
turnin g it counterclockwise. Remove the
discharge lock nut from the discharge
tube. (See Figure 73.)
Figure 73
10. Remove the lid by sliding it off the
discharge tube.
11. Remove the cylinder from the valve body.
(See Figure 74.)
Figure 74
12. Remove the discharge tube from the
valve body. (See Figure 75.)
Figure 75
13. Remove the 1-5/16” o-ring from the valve
body, and remove the 1” o -ring from the
discharge tube.
CleaningtheSyrupPump
1. Wash and scrub all parts in McD All
Purpose Super Concentrate (APSC)
(HCS).
2. Insert the black shielded brush through
the tip of the discharge tube. Move the
brush back and forth to scrub the tip of
the discharge tube. (See Figure 76.)
Figure 76
3. Advance the brush completely through
the discharge tube and pull the brush
from the bottom of the tube.
Downloaded from www.dlmanuals.com