Taylor McDonald's C602 - TROUBLESHOOTING GUIDE; Soft Lock Message Causes and Corrections

Taylor McDonald's C602
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
Faults Occurring Entering a Heat Treatment
Cycle
POWER SWITCH OFF - The power switch is
OFF.
AUTO OR STBY OFF - The control was not in
AUTO or STANDBY.
MIX OUT FAILURE - A mix out condition was
present.
NO HEAT CYCLE TRIED - The Auto Heat
Time was set to attempt a heat cycle more
than 24 hours after the last successful heat
cycle.
Faults Occurring While in Heat Mode
HEAT MODE FAILURE - The maximum
allo wable heat mode time exceeded 90
minutes.
COOL MODE FAILURE - The maximum
allo wable cool mode time exceeded 120
minutes.
TOTAL TIME FAILURE - The maximum
allowable total heat treatment time exceeded
4 hours.
BRUSH CLEAN TIMEOUT - The total days in
operation exceeded the brush clean cycle
setting.
POWER SWITCH OFF - The power switch
was turned OFF during the heat cycle.
POWERFAILINH/C-A power failure
occurre d during the heat treatment cycle.
(L/R) MIX LOW FAILURE - The mix level in
the (left/right) Hopper is too low for a
successful heat cycle.
(L/R) BEATER OVLD H/C - The overload
tripped for the (left/right) sid e beater motor.
(L/R) BRL THERM FAIL - The thermistor
sensor for the (left/right) side barrel failed.
(L/R) HOPPER THERM FAIL - The thermistor
sensor for the (left/right) side hopper failed.
(L/R) HPCO H/C - The (le ft/right) side high
pressure switch opened during the heat
treatment cycle.
Faults Occurring While in AUTO Mode
(L/R) HPR>41F (5C) AFTER 4 HR - The mix
temperature in the left or right hopper was
above 41
_F(5_C) more than four hours.
(L/R) BRL>41F (5C) AFTER 4 HR - The mix
temperature in the left or right barrel was
above 41
_F(5_C) more than four hours.
(L/R) HPR>45F (7C) AFTER 1 HR - The mix
temperature in the left or right hopper was
above 45
_F(7_C) more than one hour.
(L/R) BRL>45F (7C) AFTER 1 HR - The mix
temperature in the left or right barrel was
above 45
_F(7_C) more than one hour.
(L/R) HPR>41F (5C) AFTER PF - The mix
temperature in the left or right hopper was
above 41
_F(5_C) more than four hours
following a power failure.
(L/R) BRL>41F (5C) AFTER PF - The mix
temperature in the left or right barrel was
above 41
_F(5_C) more than four hours
following a power failure.
(L/R) HPR>59F (15C) - The mix temperature
in the left or right hopper exceeded 59
_F
(15
_C).
(L/R) BRL>59F (15C) - The mix temperature
in the left or right barrel exceeded 59
_F
(15
_C).
The HEAT CYCLE SUMMARY screen
displays the hours since the last heat cycle,
the hours since the product temperature was
above 150
_F (65.6_C), and the number of
heat cycles completed since the last brush
clean date. (See Figure 198.)
HEAT CYCLE SUMMARY
HRS SINCE HC 0
HRS SINCE 150 0
HC SINCE BC 0
Figure 198