83
The MIX LEVEL AUDIBLE option when
enabled will alert the operator with an audible
tone when there is mix low or mix out
condition. The following screen is displayed
upon selecting this option. (See Figure 195.)
MIX LEVEL AUDIBLE
> Enable
Disable
Figure 195
Disable the audible tone feature by selecting
the AUTO symbol
to move the arrow to
DISABLE. Select the CALIBRATION symbol
to save the new setting and return to the
Menu. The control panel icons for Mix Low
and Mix Out will light as the mix level drops in
the hopper but the audible tone will be
disabled.
The FAULT DESCRIPTION display will
indicate if there is a fault with the freezer and
the side of freezer where the fault occurred.
When no faults are detected the following
screen will be displayed. (See Figure 196.)
FAULT DESCRIPTION
L: NO FAULT FOUND
R: NO FAULT FOUND
Figure 196
Select the CALIBRATION symbol to
display the next fault found or return to the
Menu if no other faults exist. Selecting the
CALIBRATION symbol
any time faults are
displayed will clear the faults if corrected, upon
returning to the Menu screen.
Listed below are the variable messages which
will appear, along with an explanation for the
corrective action.
NO FAULT FOUND - There was no fault
found in the freezer. Nothing will appear on
the screen after this variable message
appears.
BEATER OVERLOAD - Press the beater
reset button firmly for the side of the freezer
with the fault. (See page 33.)
HPCO COMPRESSOR - Place the power
switch in the OFF position. Wait 5 minutes for
the machine to cool. Place the power switch in
the ON position and restart each side in
AUTO.
HOPPER THERMISTOR BAD - Place the
power switch in the OFF position. Call service
technician.
BARREL THERMISTOR BAD - Place the
power switch in the OFF position. Call service
technician.
GLYCOL THERMISTOR BAD - Place the
power switch in the OFF position. Call service
technician.
The LOCKOUT HISTORY screen displays a
history of the last 40 soft locks, hard locks,
brush clean dates, or aborted heat cycles.
Page numbers are indicated in the upper right
hand corner. Page 1 always contains the most
recent failure. (See Figure 197.)
LOCKOUT HISTORY 2
00/00/00 00:00
Reason
> Exit
Figure 197
The second line of the screen displays the
date and time a failu re occurs. The third line
indicates the reason for a failure, or will
indicate if a successful brush cleaning has
occurred. Some failures occur with multiple
reasons. When this occurs, a page will be
generated for each reason.
Select the AUTO symbol
or OPTIONAL
FLAVOR symbol
to advance forward or
backward to view each screen. Listed below
are the variable messages that may appear.
Downloaded from www.dlmanuals.com