86
Listed below are variable failure code
messages which could appear on line 2.
HT HEAT TIME FAILURE
Mix temperature did not rise above
151
_F (66.1_C) in less than 90 minutes.
CL COOL MODE FAILURE
Mix temperature in the hopper and
freezing cylinder did not fall below 41
_F
(5
_C) in less than 120 minutes.
TT TOTAL TIME FAILURE
The heat treatment cycle must be com-
pleted in no more than 4 hours.
MO MIX OUT FAILURE
A mix out condition was detected at the
start or during the heat cycle.
ML MIX LOW FAILURE
The Heat Phase or Cool Phase time
was exceeded and a mix low condition
was present.
BO BEATER OLVD IN HC
A beater overload occurred during the
heat cycle.
HO HPCO IN HEAT CYCLE
A high pressure cut -out condition oc-
curre d during the heat cycle.
PF POWER FAILURE IN HC
A power failure caused the Heat Phase,
Cool Phase, or Total Cycle Time to
exceed the maximum allowed time. If a
power failure occurs, but the heat
treatment cycle does not fail, an
asterisk(*) will appear on the third line
of the display.
PS POWER SWITCH OFF
The power switch was placed into the
OFF position during the heat cycle.
TH THERMISTOR FAILURE
A thermistor probe has failed.
OP OPERATOR INTERRUPT
Indicates the heat cycle was aborted in
the OPERATOR INTERRUPT option in
the Service Menu.
PD PRODUCT DOOR OFF
A product door is not in place or is
loose.
The SYSTEM INFORMATION is displa yed on
three separate screens. The first screen
contains the control and software version
installed in the machine. (See Figure 202.)
SOFTWARE VERSION
SERIES C600 UVC3
VERSION 1.04
> Next
Figure 202
Select the CALIBRATION symbol to
advance to the next system information screen
containing the software language version.
(See Figure 203.)
Language
v2.00 English 621
> Next
Figure 203
Select the CALIBRATION symbol to
advance to the third system information
screen containing the model bill of material
and machine serial number. Selecting the
CALIBRATION symbol
again will return to
the Menu list. (See Figure 204.)
B.O.M. C60233B000
S/N K0000000
> Next
Figure 204