97
Problem Shake Side
Probable Cause
Soft Serve Side
Probable Cause
Either Side
Probable Cause
Corrective Action
Syrup continues
Air in syrup line. Follow syrup prime procedure.
w
drawing a
shake.
Duckbill valve
damaged.
Remove syrup nose fitting and clean.
Replace duckbill valve.
Spinner shaft
will not rotate to
Flexible coupling is
broken.
Call an authorized service technician.
blend mix and
syrup.
Pin is missing in quick
disconnect of spinner
coupling.
Call an authorized service technician.
Spinner motor is out
on thermal overload.
Allo w the spinner motor to cool. Check
lubrication on the spinner shaft.
Syrup toppings
are not hot.
Topping heaters not
ON
Select topping heater symbols. Symbols will
be lit when heaters are ON.
No water is in topping
well.
Fill to indicating mark.
The water is not hot
enough.
Using a thermometer, check the water
temperature in the topping well. It should be
140
_ F(60_C).
Downloaded from www.dlmanuals.com