Model PH90Operating Procedures
Step 13
Press the WASH and PUMP keypads to stop the
W ASH and PUMP modes. Close the draw valve.
Figure 61
Note: Be sure your hands are clean and sanitized
before going on in these instructions.
Step 14
Place the agitator on the agitator drive shaft housing.
Note: To stop agitator movement, press the CAL
keypad. The agitator will continue movement after 10
seconds have elapsed.
Figure 62
Note: If the agitator paddle should stop turning during
normal operation, with sanitized hands, remove the
agitator from the agitator drive shaft housing and brush
clean with sanitizing solution. Install the agitator back
onto the agitator drive shaft housing. Press the CAL
keypad to stop rotation.
Step 15
Remove the restrictor cap.
Step 16
Return to the freezer with a small amount of sanitizing
solution. With a pail below the door spout, dip the door
spout brush into the sanitizing solution and brush clean
the syrup ports in the freezer door, door spout, bottom
of the driven spinner and spinner blade, and syrup line
fittings.
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the brush in sanitizing solution.
Step 17
With the syrup port brush, brush each syrup port hole
10 to 15 times. Dip the brush in sanitizing solution
before brushing each port.
Step 18
Fill the squeeze bottle with sanitizing solution. With a
pail beneath the door, insert the adapter end of the
squeeze bottle into the syrup port, and squeeze the
bottle firmly. This action will force solution out of the
adjacent port and down around the spinner. This
procedure should be performed for at least 10 seconds
per port.
Step 19
Install syrup valves and the restrictor cap.