Model PH90Operating Procedures
Manual Brush Cleaning
This Procedure Must Be Done Every 14 Days!
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble the Model PH90, the following items
will be needed:
S T wo cleaning and sanitizing pails for each side
of the freezer
S Necessary brushes (provided with freezer)
S Approved cleaning/sanitizing solution with
active chlorine concentrate of 100 - 200 PPM
S Single service towels
S Parts trays
Draining Product From The
Freezing Cylinder
To drain the product from the freezing cylinder for both
sides, the steps will be the same. Therefore, first drain
the product from the shake side, then go back and
duplicate these procedures for the soft serve side.
Step 1
Place the heater switches in the OFF position.
Step 2
Cancel automatic operation by pressing the AUTO
keypad.
Figure 124
Step 3
Remove the shake cup holder . Set it aside for cleaning
later with all parts. (Shake side only)
Step 4
Remove the hopper cover and agitator. Take these
parts to the sink to wash, rinse and sanitize.
Step 5
With a pail under the door spout, press the WASH and
PUMP keypads. Open the draw valve and start to drain
the product from the freezing cylinder and mix hopper.
Figure 125
Step 6
When the flow of product stops, press the WASH and
PUMP keypads and close the draw valve. Discard
this product.
Figure 126