45
Model PH90 Operating Procedures
Step 7
Return to the freezer with a small amount of cleaning
solution. Dip the door spout brush into the cleaning
solution and brush clean the door spout and bottom of
the draw valve.
Note: To assure sanitary conditions are maintained,
brush each item for a total of 60 seconds, repeatedly
dipping the brush in cleaning solution.
Figure 77
Step 8
Remove, clean and reinstall the long drip pan through
the front panel and the two short drip pans in the rear
panel.
Figure 78
Step 9
Remove, clean and reinstall the two notched drip pans
in the left and right side panels.
Figure 79
Step 10
Rinse a single service towel in cleaning solution and
wipe down the freezer door and the area around the
bottom of the freezer door .
Note: Once the heating cycle has started, it cannot be
interrupted. The heating cycle will take a maximum of
4 hours to complete with full hoppers.
CAUTION: Do not draw product during the
heating cycle because of high product
temperatures.
When the heating cycle is complete, the control will
return to the STANDBY mode.
There are 3 phases of the heat cycle: Heating, Holding
and Cooling. Each phase has a time limit. If any one
of the three phases fail to reach the proper
temperatures within the time limit, the cycle will
automatically abort and return to the STANDBY mode.
The LCD will display the message: HEAT TREAT
CYCLE FAILURE - FREEZER LOCKED - PRESS
SEL KEY. The product may not be safe to serve. The
freezer will be locked out of the AUTO mode. Discard
the product and brush clean the machine.