4-178
■ Write: Use the following steps to write in the parameter settings of the operation
interface of digital operator to the inverter.
Steps LCD Display (English) Description
1
Select the copy function group (16) from the groups menu.
2
Press the Data / Enter key and select the parameter (16-07)
display of copy function.
3
Press the Data / Enter key to display the data setting / read
screen. (the digital is reversed video and flicker).
4
Change the set value to 2 (write) by using increase key.
5
. Use data/enter key to enable the write operation, the display is
shown as the left.
. The bottom of LCD display will show a bar to indicate the write
progress.
-ADV-
WRITE
COMPLETE
“WRITE COMPLETE” will be displayed on the digital operator
interface after writing is successful.
6
.The error message of " WRE Write Error " may occur in the
memory of the interface when storing the inverter parameter
settings to the digital operator.
. If the error is displayed, press any key to remove the error
message and back to the display 16-07.
7
when DSP/FUN key is pressed, the display returns to the
sub-directory (16-07)