4-105
Group 03 External Digital Input and Output Parameters
03- 00 Multi-function input terminal S1
03- 01 Multi-function input terminal S2
03- 02 Multi-function input terminal S3
03- 03 Multi-function input terminal S4
03- 04 Multi-function input terminal S5
03- 05 Multi-function input terminal S6
Range
【0】: Forward/Stop command
【1】: Reverse/Stop command
【2】: Multi-speed/position setting command 0
【3】: Multi-speed/position setting command 1
【4】: Multi-speed/position setting command 2
【5】: Multi-speed/position setting command 3
【6】: Forward jog run command
【7】: Reverse jog run command
【8】: UP frequency increasing command
【9】: DOWN frequency decreasing command
【10】: Acceleration/deceleration time selection 2
【11】: Inhibit Acceleration/deceleration command
【12】: Main/ Alternative Run Switch Function
【13】: Main/ Alternative Frequency Switch Function
【14】: Emergency Stop (decelerate to zero and stop)
【15】: External Baseblock Command(rotation freely to stop)
【16】: PID control disable
【17】: Fault reset (Reset)
【18】: Auto Run Mode Enable
【19】: Speed Search (ffrom the maximum frequency)
【20】: Energy Saving (V/F mode only)
【21】: Reset PID Integral Value to Zero
【22】: Counter Input
【23】: Counter Reset
【24】: PLC Input
【25】: Pulse-In Width Measure(S3)
【26】: Pulse-In Frequency Measure (S3)
【27】: Local/Remote Selection
【28】: Remote Mode Selection
【29】: Jog Frequency Selection
【33】: DC Braking
【34】: Speed Search 2 (From The Frequency Command)
【40】: Switching Between Motor 1/Motor 2
【47】: Fire Mode
【48】: KEB Acceleration
【57】: Forced Frequency Run
【63】: Switch to Constant Pressure 2
【65】: Short-Circuit Breaking
【66】: PID Control Disable 2
【68】: External Fault
【69】: External Overload
Refer to the multi-function digital input and parameters in the following figure 4.3.16