4-19
Group 01 V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F SLV
PM
SLV
01-00 Volts/Hz Patterns 0~FF F - O X X *3
01-02
Maximum Output Frequency o
f
Motor 1
4.8~599.0 50.0/60.0 Hz O O X *8
01-03
Maximum Output Voltage of
Motor 1
200V:0.1~255.0 230.0
VO X X *8
400V:0.2~510.0 400.0
01-04
Middle Output Frequency 2 of
Motor 1
0.0~599.0 0.0 Hz O X X
01-05
Middle Output Voltage 2 of
Motor 1
200V:0.0~255.0
400V:0.0~510.0
0.0 V O X X *8
01-06
Middle Output Frequency 1 of
Motor 1
0.0~599.0 2.5/3.0 Hz O X X *8
01-07
Middle Output Voltage 1 of
Motor 1
200V:0.0~255.0
400V:0.0~510.0
KVA V O X X *8
01-08
Minimum Output Frequency of
Motor 1
0.0~599.0
V/F: 1.3/1.5
Hz O O O SLV: 0.5/0.6
PMSLV: 10.0
01-09
Minimum Output Voltage of
Motor 1
200V:0.0~255.0
400V:0.0~510.0
KVA VO X X *8
01-10 Torque Compensation Gain 0.0~2.0 0.5 - O X X *1
01-11
Selection of Torque
Compensation Mode
0:Mode 0 (Normal)
1:Mode 1 (High Speed)
0 - O X X
01-12 Base Frequency of Motor 1 4.8~599.0 50.0/60.0 Hz O O X *8
01-13
Base Output Voltage of
Motor 1
200V:0.0~255.0 230.0
VO X X *8
400V:0.0~510.0 400.0
01-14 Input Voltage Setting
200V:55.0~255.0 230.0
VO O O *8
400V:10.0~510.0 400.0
01-15 Torque Compensation Time 0~10000 200 ms O X X
01-16
Maximum Output Frequency o
f
Motor 2
4.8~599.0 50.0/60.0 Hz O X X *8
01-17
Maximum Output Voltage of
Motor 2
200V:0.1~255.0 230.0
VO X X *8
400V:0.2~510.0 400.0
01-18
Middle Output Frequency 2 of
Motor 2
0.0~599.0 0.0 Hz O X X
01-19
Middle Output Voltage 2 of
Motor 2
200V:0.0~255.0
400V:0.0~510.0
0.0 V O X X
01-20
Middle Output Frequency 1 of
Motor 2
0.0~599.0 2.5/3.0 Hz O X X
*8
01-21
Middle Output Voltage 1 of
Motor 2
200V:0.0~255.0
400V:0.0~510.0
KVA V O X X
*8
01-22
Minimum Output Frequency of
Motor 2
0.0~599.0 1.3/1.5 Hz O X X
01-23
Minimum Output Voltage of
Motor 2
200V: 0.0~255.0
400V: 0.0~510.0
KVA V O X X *8
01-24 Base Frequency of Motor 2 4.8~599.0 50.0/60.0 Hz O X X *8
01-25
Base Output Voltage of
Motor 2
200V: 0.0~255.0 230.0
VO X X *8
400V: 0.0~510.0 400.0
01-26
V/F Curve Selection of Motor 2
0~FF F - O X X *3