4-18
Group 00 Basic Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F SLV
PM
SLV
00-10
Initial Frequency
Selection (keypad mode)
0:by Current Frequency Command
1:by 0 Frequency Command
2:by 00-11
0 - O O O
00-11
Initial Frequency Setpoint 0.00-599.00
50/60 Hz O O O *1
00-12 Frequency Upper Limit 0.00-599.00 0.0 Hz O O O
00-13 Frequency Lower Limit 0.00-599.00 0.0 Hz O O O
00-14 Acceleration Time 1 0.1~6000.0 * s O O O
*1
00-15 Deceleration Time 1 0.1~6000.0 * s O O O
*1
00-16 Acceleration Time 2 0.1~6000.0 * s O O O
*1
00-17 Deceleration Time 2 0.1~6000.0 * s O O O
*1
00-18 Jog Frequency 0.00~599.00 2.00 Hz O O O
*1
00-19 Jog Acceleration Time 0.1~0600.0 * s O O O
*1
00-20 Jog Deceleration Time 0.1~0600.0 * s O O O
*1
00-21 Acceleration Time 3 0.1~6000.0 * s O X X
*1
00-22 Deceleration Time 3 0.1~6000.0 * s O X X
*1
00-23 Acceleration Time 4 0.1~6000.0 * s O X X
*1
00-24 Deceleration Time 4 0.1~6000.0 * s O X X
*1
00-26 Emergency Stop Time 0.1~6000.0 5.0 s O O O
00-27
HD/ND Mode
(F5/F6 Only)(***)
0:HD (Heavy Duty Mode)
1:ND (Normal Duty Mode)
0 - O X X *3
00-34 Language
0:English
1:Simplified Chinese
2:Traditional Chinese
3:Turkish
0 - O O O *7
00-35
Minimum Frequeny
Detection
0:Alarm
1:Keep Running At Lower Frequency
0:Disable
(Lower Frequency of PID Sleep Mode)
1:Enable (0Hz of PID Sleep Mode)
0 - O O O
00-36
PID Lower Frequency
Selection
0 - O O O
*:
***:
Refer to the following attachment 1.
If parameter 00-27 is set to ND mode, group 02 motor 1 parameter will automatically adjust to more
than 1 class of it.
If parameter 00-27 is set to HD mode, group 02 motor 1 parameter will automatically adjust to the
same class of it.
It is suggested that parameter 00-27 be set first before motor performs auto-tuning because the parameter
will make the motor parameter automatically be changed.