4-24
Group 04 Analog signal inputs / Analog output
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F SLV
PM
SLV
04-00 Analog Input Signal Type
0:AI1 0~10V
AI2 0~10V / 0~20mA
1:AI1 0~10V
AI2 4~20mA / 2~10V
2:AI1 2~10V
AI2 0~10V / 0~20mA
3:AI1 2~10V
AI2 4~20mA / 2~10V
1 - O O O
04-01
AI1 Signal Scanning and
Filtering Time
0.00~2.00 0.03 s O O O
04-02 AI1 Gain 0.0~1000.0 100.0 % O O O *1
04-03 AI1 Bias -100.0~100.0 0 % O O O *1
04-05 AI1 Slope
0:Positive
1:Negative
0 - O O O
04-06
AI2 Signal Scanning and
Filtering Time
0.00~2.00 0.03 s O O O
04-07 AI2 Gain 0.0~1000.0 100.0 % O O O *1
04-08 AI2 Bias -100.0~100.0 0 % O O O *1
04-10 AI2 Slope
0:Positive
1:Negative
0 - O O O
04-11 Analog Output (AO) Mode
0:Output Frequency
1:Frequency Command
2:Output Voltage
3:DC Bus Voltage
4:Output Current
0 -
O O O
O O O
O O O
O O O
O O O
04-12 AO Gain 0.0~1000.0 100.0 % O O O *1
04-13 AO Bias -100.0~100.0 0 % O O O *1
04-15 AO Slope
0:Positive
1:Negative
0 - O O O
04-16 F-Gain
0:Disable
1:Enable
0 - O O O
04-20
AO Signal Scanning and
Filtering Time
0.00~0.50 0.00 s O O O *1
04-22 AO voltage correction
0:Disable
1:Enable
0 - O O O