5-73
Pn315.1 = 0
Work
platform
Servo motor
CWL
(Negative limit)
CCWL
(Positive limit)
Home
Sensor
Origin reset
operation
Offset moves
Un-14 = 0
Un-16 = 0
Pn315.1 = 1
Work
platform
Servo motor
CWL
(Negative limit)
CCWL
(Positive limit)
Home
Sensor
Origin reset
operation
Offset does not move
Un-14 = Pn321
Un-16 = Pn320