5-159
Pn349 Full-closed loop operation direction setting
Initial Value Unit Setting Range Effective RS-485
0 -- 0~1 Power Re-set 033CH
Setting Description: It is necessary to consider main axle feedback direction when choosing the
physical main axle. AL.023 will occur when the direction is incorrect.
Setting Description
0 Phase A leading phase B
1 Phase B leading phase A
Rotary cut function description
Fig 5.3 Rotary cut diagram
Set flying shear to 2 by EC901 and Cn001=6 (activate flying shear function) to plan flying shear
function. The user can plan according to actual disc distribution and select virtual main axle
(automatic planning) or physical main axle (feeding axle feedback planning) by EC902.0 (feedback
source selection) for setting. If the user chooses the physical main axle (feeding axle feedback
planning) to set, the main axle encoder feedback must be connected to CN8 slot. When E-Cam
function and feedback source selection are determined, the user can start setting the associated
parameters of master and slave as follows:
Feeding direction
Feeding axle
Cutting axle