7-68
Sn213 Speed Loop Gain 2
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
40 Hz
2 ~ 1500 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
020DH 220DH 220DH O O O O -
Setting Description: Please refer to Sn211 Description for Setting Method
Sn214 Speed Loop Integration Time Constant 2
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
2000 0.01ms 40 ~ 50000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
020EH 220EH 220EH O O O O -
Setting Description: Please refer to Sn212 Description for Setting Method
Sn215 Zero Speed Determined Value
5-3-7
Initial Value Unit Setting Range Effective Cn029 Reset
50 rpm 0 ~ 1.5*Rated Speed -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
020FH 220FH 220FH O O O O O
Setting Description: When speed is lower than the speed set by Sn215 (zero speed determined value), digital output
contact ZS activates.