7-70
Sn218 Analog speed command limit
JSDG2S-E(L) does not have this function
5-3-
3
Initial Value Unit Setting Range Effective Cn029 Reset
1.02*
Rated Speed
rpm
100 ~ 1.5*Rated Rotational
Speed
-- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0212H - - -- -- -- O --
Setting Description: The user can set Sn218 to limit the Maximum Speed of the Analog Input.
Sn226 Analog speed command filter
5-3-2
Initial Value Unit Setting Range Effective Cn029 Reset
0 Hz
0~2500 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0220H 2220H 2220H -- -- -- O O
Setting Description: Set SIC analog speed command stop frequency, if set 2500, it means 25000Hz.
Sn227 ZS zero speed determine signal delay time
5-3-2
Initial Value Unit Setting Range Effective Cn029 Reset
0
ms
0~5000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
021BH 221BH 221BH -- -- -- O O
Setting Description: When the Sn215 zero speed judgment value is met, and the time is greater than the Sn227 setting
time, the ZS signal output.